REVIEW ARTICLE


Review of Guidelines for Seismic Design of Structures with Damping Systems



Sonia E. Ruiz*
Instituto de Ingeniería, Universidad Nacional Autónoma de México, Coyoacán, 04510, Ciudad de Mexico, Mexico


Article Metrics

CrossRef Citations:
4
Total Statistics:

Full-Text HTML Views: 834
Abstract HTML Views: 368
PDF Downloads: 297
ePub Downloads: 200
Total Views/Downloads: 1699
Unique Statistics:

Full-Text HTML Views: 548
Abstract HTML Views: 275
PDF Downloads: 252
ePub Downloads: 175
Total Views/Downloads: 1250



Creative Commons License
© 2018 Sonia E. Ruiz.

open-access license: This is an open access article distributed under the terms of the Creative Commons Attribution 4.0 International Public License (CC-BY 4.0), a copy of which is available at: (https://creativecommons.org/licenses/by/4.0/legalcode). This license permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.

* Address correspondence to this author at the Institute of Engineering, Dept. of Structural Engineering, Universidad Nacional Autónoma de México, Coyoacan, 04510 Ciudad de Mexico, Mexico. Tel: 52 (55) 56233654, E-mail: sruizg@iingen.unam.mx


Abstract

Objective:

The purpose of this paper is to present an overview of the specifications of three guidelines for the seismic design of structures with passive dampers, to compare their similarities, as well as to discuss topics in which each guideline would be desirable to extend. The guidelines compared here are: a) Minimum Design Load for Buildings and Other Structures (ASCE/SEI 7-16), b) European Standard Anti-seismic Devices (EN 15129), and c) Technical Regulations for Seismic Design, corresponding to Mexico City Building Code (NTCS-17).

Methods:

The document summarizes and discusses the most significant differences and similarities among the three guidelines for the design of structures with energy dissipation devices. The analysis and discussion are focused on the following sections: 1) Type of Dissipation Devices, 2) General Design Requirements, 3) Procedure Selection, 4) Seismic Design Action, 5) Inspection and 6) Testing of Dissipaters.

Conclusion:

The paper identifies the gaps in each guideline and gives recommendations about its possible extension. The paper concludes that ASCE/SEI 7-16 presents the procedure selection section with more detail; EN 15129 describes with more detail the Testing section, and NTCS-17, the Inspection section. The paper can be useful for engineers and guideline writers from the USA, Europe, Mexico and other countries that are in process of developing their guidelines for structures with supplementary damping.

Keywords: Buildings with dampers, Energy dissipating devices, American, Mexican and European design recommendations, Anti Seismic Devices, Testing of Dissipater, Seismic Design Action.