RESEARCH ARTICLE


Experimental Investigation of Skirt Footing Subjected to Lateral Loading



Faris Waleed Jawad1, Abbas Fadhil Ibrahim Al-Ameri2, *, Azhar Sadiq Yasun3
1 Department of Reconstruction and Projects, Ministry of Higher Education and Scientific Research, Baghdad, Iraq
2 Department of Civil Engineering, College of Engineering, University of Baghdad, Baghdad, Iraq
3 Department of Civil Engineering, College of Engineering, AL-Nahrain University, Baghdad, Iraq


Article Metrics

CrossRef Citations:
2
Total Statistics:

Full-Text HTML Views: 1138
Abstract HTML Views: 494
PDF Downloads: 349
ePub Downloads: 278
Total Views/Downloads: 2259
Unique Statistics:

Full-Text HTML Views: 666
Abstract HTML Views: 324
PDF Downloads: 274
ePub Downloads: 214
Total Views/Downloads: 1478



Creative Commons License
© 2019 Jawad et al.

open-access license: This is an open access article distributed under the terms of the Creative Commons Attribution 4.0 International Public License (CC-BY 4.0), a copy of which is available at: (https://creativecommons.org/licenses/by/4.0/legalcode). This license permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.

* Address correspondence to this author at the Department Civil Engineering, University of Baghdad, Baghdad, Iraq; Tel: (00964) 7901312585; E-mail: alameri.abbas@gmail.com


Abstract

Background:

The skirt foundation is one of the powerful types of foundations to resist the lateral loads produced from natural forces, such as earthquakes and wind action, or from the type of structures, such as oil platforms and offshore wind turbines.

Objective and Methodology:

This research experimentally investigated the response of skirted footing resting on sandy soil of different states to lateral applications of loads on a small-scale physical model manufactured for this purpose. The parameters studied are the distance between the footing and the skirt and its depth.

Results and Conclusion:

The results show that the presence of the skirt behind the footing loads to an increase in bearing load and a reduction in the lateral movement whereas the skirt near or adjacent to the footing edge causes maximum increases in bearing load and reduction in lateral movement, for skirted footing. The ratio between the wall distance and the width of the footing has no effect when it is greater than one. On the other hand, the state of the soil influences the bearing load and lateral movement with different ratio of wall distance and wall depth to the width of the footing, especially when the wall distance to the footing width is less than one and the state of the soil has no effect on the bearing load and lateral movement when the ratio is more than one.

Keywords: Skirt, Foundation, Sand, Lateral loading, Lateral movement, Physical model test.