RESEARCH ARTICLE


Influence of Local Site Effects on the Typological Fragility Curves for Class-Oriented Masonry Buildings in Aggregate Condition



Antonio Formisano1, *, Nicola Chieffo2, Francesco Clementi3, Marius Mosoarca2
1 Department of Structures for Engineering and Architecture, School of Polytechnic and Basic Sciences, University of Naples “Federico II” 80125 Naples, Italy
2 Faculty of Architecture and Urbanism, Politehnica University of Timişoara, Traian Lalescu Street, 300223 Timișoara, Romania
3 Department of Civil and Building Engineering and Architecture, Polytechnic University of Marche Via Brecce Bianche, 60131 Ancona, Italy


Article Metrics

CrossRef Citations:
9
Total Statistics:

Full-Text HTML Views: 614
Abstract HTML Views: 268
PDF Downloads: 313
Total Views/Downloads: 1195
Unique Statistics:

Full-Text HTML Views: 452
Abstract HTML Views: 179
PDF Downloads: 259
Total Views/Downloads: 890



Creative Commons License
©2021 Formisano. et al.

open-access license: This is an open access article distributed under the terms of the Creative Commons Attribution 4.0 International Public License (CC-BY 4.0), a copy of which is available at: https://creativecommons.org/licenses/by/4.0/legalcode. This license permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.

* Address correspondence to this author at Department of Structures for Engineering and Architecture, School of Polytechnic and Basic Sciences, University of Naples “Federico II” 80125 Naples, Italy;
E-mail: antoform@unina.it


Abstract

Background:

The Municipality of Baranello, located in the province of Campobasso, is considered as a reference case study for implementing a systematic procedure for the assessment of local site effects. The territory is characterised by a heterogeneous soil, made of a basal interval formed in large part by outcrops found along with the middle-basal bands of the local slopes, which is particularly sensitive to geo-hazard effects.

Aims:

The present work aims to investigate the influence of local site effects on the seismic vulnerability of an oriented- class of masonry building compounds. The historical buildings surveyed are mainly made up of rough stone masonry, particularly vulnerable to seismic phenomena. The buildings are appropriately grouped in typological classes based on the CARTIS form and then subdivided into different categories according to the EMS-98 scale based on their geometrical and structural characteristics.

Methods:

The performed vulnerability analysis is based on a vulnerability-index method conceived for buildings grouped in aggregate condition. Moreover, the expected damage scenario is properly evaluated based on a specific attenuation law to take into consideration the effect produced by a reference scenario event. Furthermore, the local site conditions have been evaluated based on a 1D half space approach in order to predict the possible increment of the expected damage due to the soil stratigraphy.

Results:

The local site conditions provide a global increment of the expected vulnerability of 33% with respect to the case in which the geo-hazard effects are neglected. In this activity framework, typological fragility curves are derived for comparing the exceeding probability thresholds for the examined building classes.

Conclusion:

The proposed research represents an important starting point for large-scale vulnerability assessment since it provides a simplified and comprehensive method for predicting seismic damage scenarios of historic center considering local site effects.

Keywords: Vulnerability assessment, Masonry building compounds, Large-scale analysis, Damage scenarios, Site effects, Attenuation law, Vulnerability curves, Fragility curves.