Bond of High Strength Concrete with High Strength Reinforcing Steel
RESEARCH ARTICLE

Bond of High Strength Concrete with High Strength Reinforcing Steel

Muhammad N.S. Hadi, * Open Modal
Authors Info & Affiliations
The Open Civil Engineering Journal 26 Nov 2008 RESEARCH ARTICLE DOI: 10.2174/1874149500802010143

Abstract

This paper presents a study about the bond of high strength concrete with high strength steel. Fourteen pull out tests were carried out to determine the bond. The concrete strength was about 70 MPa and the steel was a 500 MPa grade. Bar diameters used were 12, 16, 20, 25, 28, 32 and 36 mm. In order to investigate the effect of cover, each test was done twice, once in a 240 mm diameter concrete cylinder and the second in a 300 mm diameter cylinder. Based on the test results a new equation representing the bond is proposed.

Keywords: Reinforced concrete, Bond, High strength concrete, High strength steel.