REVIEW ARTICLE


A Review on the Characteristics of the Smear Zone: Field Data Back Calculation Compared with Laboratory Testing



Rudi Iskandar, A Perwira Mulia Tarigan*, Roesyanto
Department of Civil Engineering, Post Graduate Study Program, Faculty of Engineering, University of Sumatera Utara, Kampus USU, Medan 20155, Indonesia


Article Metrics

CrossRef Citations:
1
Total Statistics:

Full-Text HTML Views: 1694
Abstract HTML Views: 333
PDF Downloads: 358
ePub Downloads: 183
Total Views/Downloads: 2568
Unique Statistics:

Full-Text HTML Views: 949
Abstract HTML Views: 260
PDF Downloads: 301
ePub Downloads: 162
Total Views/Downloads: 1672



Creative Commons License
© 2018 Iskandar et al.

open-access license: This is an open access article distributed under the terms of the Creative Commons Attribution 4.0 International Public License (CC-BY 4.0), a copy of which is available at: (https://creativecommons.org/licenses/by/4.0/legalcode). This license permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.

* Address correspondence to this author at the Department of Civil Engineering, Post Graduate Study Program, Faculty of Engineering, University of Sumatera Utara, Kampus, Medan 20155, Indonesia; Tel: +628116069333; E-mails: a.perwira@usu.ac.id, a.perwira.mulia@gmail.com


Abstract

Background:

The so-called smear zone is a disturbed zone developed in soil during prefabricated vertical drainage (PVD) installation using a mandrel. There are 2 main parameters typically used to characterize the smear zone. First, the extent ratio signifies the extent of the soil damage due to mandrel penetration; and second, the permeability ratio κ represents the degree of disturbance to the soil permeability within the smear zone.

Objectives:

This study reviews 2 methods employed by various researchers to obtain the values for the 2 aforementioned parameters, i.e. 1) field data back calculation and 2) laboratory testing. It is found that the s’ values vary between 2.0 – 5.0 and between 2.0 – 6.3 based on field data back calculation and laboratory testing, consecutively. On the other hand, the κ values vary between 2.0 - 13.8 and 1.03 – 3.13 based on field data back calculation and laboratory testing, consecutively.

Results and Conclusion:

With regard to the previous studies, three causes of the variation are suggested in this study: 1) the laboratory testing’s inability to model the complexity of field conditions, 2) the absence of standardized laboratory methods that can be used as references and 3) the level of disturbance in the field which is considerably greater than that in the laboratory and differs at each research location. In addition to the review, historical data of a trial embankment at the embankment of the multi-purpose container yard in Kuala Tanjung, North Sumatra, Indonesia, are exhibited to illustrate the estimation of the s’ and κ values.

Keywords: Smear zone, The extent ratio, The permeability ratio, Laboratory testing, Back calculation, Numerical method, PVD installation, Soft clay, Consolidation.